Analytical HPLC-A7840
Analytical HPLC-A7840 system with 0.001 to 9.999 ml / min flow rate range, offers three method measurement: dual wavelength detection, wavelength time program and stop pump scanning. Integrated with a single and dual wavelength UV-Vis detector with a range of 190 to 700 nm to analyse sample’s absorption at different wavelengths and high-pressure pump achieves accurate solvent delivery with high-precision and low-fluctuation.
| Pump Specifications | <table class="table table-striped table-bordered table-responsive"><tr><td><strong>Solvent delivery</strong></td><td>Double plunger series mode, floating plunger design, single stroke volume 30 µl</td></tr><tr><td><strong>Pump Head</strong></td><td>10 ml stainless steel pump head</td></tr><tr><td><strong>Flow rate range</strong></td><td>0.001 to 9.999 ml / min</td></tr><tr><td><strong>Flow rate increment</strong></td><td>0.001 ml/min</td></tr><tr><td><strong>Maximum pressure</strong></td><td>42 MPa</td></tr><tr><td><strong>Column size</strong></td><td>4.6 × 250 mm 5 µm</td></tr><tr><td><strong>Pipeline Size</strong></td><td>1/16 inch</td></tr><tr><td><strong>Flow rate accuracy</strong></td><td>± 0.5 %</td></tr><tr><td><strong>Flow rate precision</strong></td><td>RSD ≤ 0.1%</td></tr><tr><td><strong>Gradient accuracy %</strong></td><td>± 0.5 %</td></tr><tr><td><strong>Gradient repeatability %</strong></td><td>RSD ≤ 0.15%</td></tr><tr><td><strong>GLP</strong></td><td>Automatic recording of pump sealing ring working time</td></tr><tr><td><strong>Display</strong></td><td>LCD backlight display</td></tr><tr><td><strong>Power</strong></td><td>80 W</td></tr><tr><td><strong>Power supply</strong></td><td>220 V ± 10%, 50 Hz</td></tr><tr><td><strong>Dimension</strong></td><td>398 × 149 × 267 mm</td></tr></table> |
| Detector Specifications | <table class="table table-striped table-bordered table-responsive"><tr><td><strong>Wavelength range</strong></td><td>190 to 700 nm</td></tr><tr><td><strong>Wavelength accuracy</strong></td><td>± 1 nm</td></tr><tr><td><strong>Wavelength repeatability</strong></td><td>0.2 nm</td></tr><tr><td><strong>Deuterium lamp</strong></td><td>190 to 400 nm</td></tr><tr><td><strong>Tungsten lamp</strong></td><td>400 to 700 nm</td></tr><tr><td><strong>Baseline noise ( Static ) Au</strong></td><td>1 × 10<sup>-5</sup> AU/h at 254 nm with methanol/water= 80/20</td></tr><tr><td><strong>Baseline drift ( Static ) Au / h</strong></td><td>1.5 × 10<sup>-4</sup> AU/h at 254 nm with methanol/ water= 80/20</td></tr><tr><td><strong>Time constants</strong></td><td>16 grades adjustable</td></tr><tr><td><strong>Display</strong></td><td>LCD backlight display</td></tr><tr><td><strong>GLP</strong></td><td>Total number of lights, lamp replacement time and product serial number</td></tr><tr><td><strong>Power</strong></td><td>75 W</td></tr><tr><td><strong>Power supply</strong></td><td>220 V ± 10%, 50 Hz</td></tr><tr><td><strong>Dimension (L × W × H)</strong></td><td>398 × 149 × 267 mm</td></tr></table> |
Used in pharmaceutical analysis, food nutrient analysis of amino acids and sugars, detection of food contaminants, environmental pollutant and chemical product purity analysis.
www.labtron.co
Labtron Equipment Ltd. Quatro House, Lyon Way, Camberley, Surrey GU16 7ER, United Kingdom
Email: info@labtron.co | Website: https://labtron.co/ | Phone: +44 2080 043 608