Generate Catalog For :

Portable Multi-parameter Water Quality Meter LMPWM-A11

Portable Multi-parameter Water Quality Meter LMPWM-A11

Portable Multi-parameter Water Quality Meter LMPWM-A11

Description :

Portable Multi-parameter Water Quality Meter LMPWM-A11 is adapted with different modes for measuring quality of water on different parameters such as pH, ORP, conductivity, TDS, salinity. Its memory can store & recalls up to 500 sets of data. Due to its portable design, it is suitable for outdoor measurements i.e. on site water testing, remote area water testing & for research purpose. It is reliable and user friendly.

Specifications :

pH mode <table class="table table-striped table-bordered table-responsive"><tr><td><strong>pH measurement range</strong></td><td>(-2.000) to 20.000 pH</td></tr><tr><td><strong>pH accuracy</strong></td><td>± 0.002 pH</td></tr><tr><td><strong>pH calibration points</strong></td><td>1 - 5 points</td></tr><tr><td><strong>pH calibration solutions</strong></td><td>USA, NIST, DIN or user defined</td></tr></table>
ORP measurement <table class="table table-striped table-bordered table-responsive"><tr><td><strong>ORP measurement range</strong></td><td>-1999.9 to 1999.9 mV</td></tr><tr><td><strong>ORP accuracy</strong></td><td>±0.2 mV</td></tr><tr><td><strong>ORP calibration points</strong></td><td>1 point</td></tr><tr><td><strong>ORP calibration solutions</strong></td><td>mV &amp; relative mV</td></tr></table>
Ion measurement <table class="table table-striped table-bordered table-responsive"></table>
Conductivity measurement <table class="table table-striped table-bordered table-responsive"><tr><td><strong>Conductivity measurement range</strong></td><td>0 - 20.00, 200.0, 2000 µS / cm, 20.00, 200.2 mS / cm</td></tr><tr><td><strong>Conductivity accuracy</strong></td><td>± 0.5 % F.S.</td></tr><tr><td><strong>Conductivity calibration points</strong></td><td>1 - 5 points</td></tr><tr><td><strong>Conductivity calibration solutions</strong></td><td>10 µS / cm, 84 µS / cm, 1413 µS / cm, 12.88mS / cm, 111.8mS / cm</td></tr><tr><td><strong>Temperature coefficient</strong></td><td>0.0 to 10.0 % / °C</td></tr><tr><td><strong>Compensation modes</strong></td><td>Linear or pre water</td></tr><tr><td><strong>Cell constant</strong></td><td>K = 0.1, 1, 10 or user-defined</td></tr><tr><td><strong>Normalization temperature</strong></td><td>20 °C or 25 °C</td></tr></table>
TDS measurement <table class="table table-striped table-bordered table-responsive"><tr><td><strong>TDS range</strong></td><td>0 to 100 ppt. (max. 200 ppt., depending on factor setting)</td></tr><tr><td><strong>TDS accuracy</strong></td><td>± 1 % F.S.</td></tr><tr><td><strong>TDS factor</strong></td><td>0.1 - 1.0 (default 0.5)</td></tr></table>
Salinity measurement <table class="table table-striped table-bordered table-responsive"><tr><td><strong>Salinity range</strong></td><td>0 to 100 ppt. (max. 80 ppt.)</td></tr><tr><td><strong>Salinity accuracy</strong></td><td>± 1 % F.S</td></tr><tr><td><strong>Measurement modes</strong></td><td>Seawater or practical salinity</td></tr></table>
Resistivity <table class="table table-striped table-bordered table-responsive"><tr><td><strong>Resistivity range</strong></td><td>0 to 100 Ω</td></tr><tr><td><strong>Resistivity accuracy</strong></td><td>± 1 % F.S</td></tr><tr><td><strong>Resistivity resolution</strong></td><td>0.01, 0.1, 1</td></tr></table>
Dissolved oxygen <table class="table table-striped table-bordered table-responsive"></table>
Temperature compensation 0 to 100 °C, 32 to 212 °F, Manual or Automatic
Stability conditions Low or high
Calibration due 0 to 31 days
Memory Stores up to 500 data sets
Output USB communication interface
Dimension (L × W × H) 185 × 88 × 32 mm
Weight 300 g
Power supply 3 × 1.5 V “AA batteries or DC 5 V power adapter

Features :

  • -  Common Features
  • -  Calibration due reminder informs operator to calibrate the meter regularly
  • -  Stability indicator displays the status of current measurement
  • -  Auto hold function freezes stable, final readings for better viewing and recording
  • -  Manual temperature calibration to rectify the deviations in temperature
  • -  Automatic temperature compensation for accurate measured value over the entire range
  • -  Selectable temperature units (°C or °F) for different application requirements
  • -  Expanded memory stores and records up to 500 readings
  • -  Help message as an operational guide, helps users for quick access to the parameters
  • -  Reset function automatically resumes all the setting back to factory default options
  • -  Store data is transferrable into computer via USB communication interface
  • -  pH mode
  • -  1-5 points push button calibration to automatically identify pH buffer
  • -  Convenient to select pH buffer standard (USA/NIST/DIN) or custom
  • -  Automatic electrode slope display helps operator whether to replace the sensor
  • -  ORP mode
  • -  1 point offset calibration to adjust the display value to known standard
  • -  Relative & absolute mV measurements for accurate ORP readings
  • -  Conductivity / TDS / Salinity / Resistivity Mode
  • -  1-5 point for calibration with automatically identification of calibration solutions
  • -  Can select cell constant (0.1/1/10) and normalization temperature (20°C or 25°C)
  • -  TDS conversion factor, seawater, practical salinity measurements mode to meet different water quality measurement requirements
  • -  Linear or pure water compensation improves the measurement accuracy

Applications :

The portable multi-parameter water quality meter is used for quality testing of water on different parameters in research and development labs, water resources and plants in nearby or remote area.

Labtron www.labtron.co

Labtron Equipment Ltd. Quatro House, Lyon Way, Camberley, Surrey GU16 7ER, United Kingdom

Email: info@labtron.co | Website: https://labtron.co/ | Phone: +44 2080 043 608