Portable infrared gas detector LIGD-A10 is a hand-held SF6 (sulfur hexafluoride) Gas detector for continuous measurement of gas. Adopted with imported gas infrared sensor, it utilizes unique method of data processing. Light emitting organic matter OLED screen, gives clear display in absence of light and when operated during dark. With Non-dispersive infrared (NDIR) principle, the detection resolution of leakage can reach up to 0.1ppm.

Measurement principle Non-dispersive infrared  (NDIR)
Gas Detected SF6: 0 to 50 ppm range/ 0 to 1000 ppm range (as per req.)
Detection Uncertainty <1.5 % F.S
Detection Resolution 0.1ppm
Sampling mode Pumping type
Probe unit rod length 22 cm
Response time 1 to 5 s
Warm-up time 100 s
Operation temperature -10 to 60℃
Display OLED self-luminous with low power consumption, high brightness
Power supply 4.2 V, internal lithium battery power supply, 2200 mAh
Shelf life >10 years
Dimension 500 × 290 × 180 mm
Weight 0.7 kg
HS Code 9027100090
  • Zero drift automatic modification
  • Imported with long shelf life sensors
  • Instant response and recovery rate
  • Multi-level speech and light alarm
  • High sensitivity data
  • USB or AC adopter charging mode
  • Data Analysis, reading by PC software through USB
  • Storage and inquiry of measurement data
Used to measure the gas leakage of switchgear, GIS, circuit breaker etc. in electronic industry, also used in greenhouse, painting, chemical industry.

Gas Detectors

Portable 2 in 1 gas detector LPTG-A10

Portable 2 in 1 gas detector LPTG-A10

  • Sampling method
  • Diffusion
  • Sensor type
  • CO2: solid electrolyte sensor, O2:electrochemical sensor
  • Detection range
  • CO2:0.04 to 5.00 % and O2:0.0 to 30.0 %
Portable 10 in 1 Multi Gas Detector LMGD-A10

Portable 10 in 1 Multi Gas Detector LMGD-A10

  • Gas Detected
  • O2 CH4 CO2 VOC CO H2S SO2 CL2 NO2 NH3
  • Detection principle
  • Electrochemical principle (O2 CO H2S SO2 CL2 NO2 NH3) Infrared principle (CH4 CO) Photoionization principles (VOC)
  • Measurement Range
  • O2: 0-30% VOL, CH4: 0-50000 PPM, CO2:0-50000 PPM VOC:0-2000 PPM, CO:0-999 PPM, H2S: 0-200 PPM SO2: 0-25 PPM, CL2: 0-50 PPM, NO2: 0-100 PPM, NH3:0-100 PPM
Portable Single Gas Detector LPSG-A10

Portable Single Gas Detector LPSG-A10

  • Sampling method
  • Diffusion
  • Measurement principle
  • Electrochemical (oxygen, toxic gases), Catalytic combustion (flammable gases), Infrared principle (carbon dioxide gas)
  • Detector gas
  • Flammable gases, oxygen gas, toxic and harmful gases
Portable Multiple Gas Detector LPMG-A10

Portable Multiple Gas Detector LPMG-A10

  • Sampling Method
  • Diffusion
  • Working conditions
  • Temperature -20 to 50°C Pressure 0.9 to 1.1 (standard atmospheric pressure) Humidity 10 to 95 % RH (no dew condensation)
  • Explosion proof grade
  • Exia II CT3

Digital Differential Pressure Meter

Digital Differential Pressure Meter LDPM-A10

Digital Differential Pressure Meter LDPM-A10

  • Measuring range
  • 0 ∼ 125 Pa
  • Accuracy
  • 0 ± 0.2 Pa (liner error) ± 1 %
  • Operating temperature range
  • 0 °C ∼ 50 °C
Digital Differential Pressure Meter LDPM-A20

Digital Differential Pressure Meter LDPM-A20

  • Measuring range
  • ± 500 Pa
  • Repeatability
  • ± 0.2 % FS
  • Resolution
  • 0.1 Pa

Handheld Ozone Tester

Handheld Ozone Tester LHOT-A10

Handheld Ozone Tester LHOT-A10

  • Measurement range
  • 0 ppm ∼ 5 ppm
  • Resolution
  • 0.001 ppm ( 0 ppm ∼ 5 ppm )
  • Temperature range
  • ˗ 40 °C ∼ 120 °C

Online Ozone Meter

Online Ozone Meter LOOM-A10

Online Ozone Meter LOOM-A10

  • Ozone measurement range
  • 0 ppm ∼ 5 ppm, 0 ppm ∼ 100 ppm, 0 ppm ∼ 300 ppm, 0 ppm ∼ 600 ppm ( Optional )
  • Flow rate
  • 1.5 L/min
  • Accuracy
  • 0.01 ppm or 3 % of reading

UV-Absorption Ozone Meter

UV Absorption Ozone Meter LUOM-A10

UV Absorption Ozone Meter LUOM-A10

  • Ozone measurement range
  • 0 ppm ∼ 100 ppm/ 0 ppm ∼ 1000 ppm
  • Flow rate
  • 1 L/min
  • Accuracy
  • 0.01 ppm