+44 2080 043 608
info@labtron.co
Home
Thermal Cycler
Lab Equipment
Analytical Instruments
Catalogs
About Us
Contact Us
Request A Quote
Company Info
Terms of Use
Policies
Site map
Home
Analytical Instruments
Environmental Monitoring Equipments
Amino Acid Analyzer
Autoclaves
Baths and Circulators
Cabinets
Centrifuge
Freezers
Freeze Dryers
Fume Hood
Muffle Furnace
Tube Furnace
Ice Makers
Incubator
Kjeldahl Systems
Laboratory Shakers and Mixers
Oven
Peristaltic Pump
Refrigerators
Spectrophotometer
Test Chamber
Thermal Cycler
Ultrasonic Cleaner
Vacuum Pump
CO2 Incubator
Thermo-Shakers
Water Purification System
Viscometer
Oven Incubator
Flame Photometer
Microplate Reader & Washer
Petroleum Testing
Solar Powered Products
Chillers
Chromatography
HPLC
Particle Size Analyzer
Gel Documentation
TOC Analyzer
Rotary Evaporator
Polarimeter
Lab Refrigerator-Freezer Combination
Spectrometer
Microscope
Colorimeters
Testing Instruments
Colony Counter
IR Carbon Sulphur Analyzer
Sample Concentrator
Safety Containment Cabinets
Water Testing
Magnetic Stirrers and Hotplates
Microtome
Nucleic Acid Purification System
Moisture Analyzer
Oil And Grease Analyzer
UV Pass Box
Pharmaceutical Testing
V-shell Blender
Differential Thermal Analyzers
Balances
Blood Collection Monitor
Particle Counter
Density Meter
Biochemistry Analyzer
Automatic Glassware Washer
Ultrasonic Homogenizer
Environmental Monitoring Equipments
Refractometer
Water Distillers
Stomacher
Airborne Particle Counters
Hybridization Oven
Platelet Agitator and Incubator
Jar Testers
Electrophoresis System
Milk Analyzers
Potentiometric Titrator
Flammability Tester
Pathology Workstation
BLOOD THAW MACHINE
Opacity Meter
Plasma Extractor
Elemental Analyzer
Plate Sealer
Dosimeter
Stroboscope
Latex Stability Tester
Drug Detector
Wind Meter (Anemometer)
Slide Dryer
Paraffin Trimmer
Vacuum Spin Coater
Ball Mill Machine
Osmometer
ESR Analyzer
Differential Scanning Calorimeters
Water Purifier
Dehumidifier
Vacuum Pycnometer
Gene Electroporator
Laminar Flow Canopy
Fume Extractor
Heating Mantle
Gel Strength Test System
Melting Point Apparatus
Vacuum Filtration Unit
Bottle Top Dispenser
Tachometer
Hydrogen Peroxide Generator
Microwave Digestion System
Sound Level Analysis
X-Ray Machine
Fiber Analysis
Fluorometer
Hybridization System
Semi-automatic Bio-chemistry Analyzer
Soxhlet Apparatus
Color Assessment Cabinet
Leather Softness Tester
Washer Disinfector
Vacuum Packing machine
Glassware Drying Cabinet
Metal Detector
Alloy Analyzer
Blood Bag Tube Sealer
Handheld Homogenizer
Fluorescence Analyzer
Air Permeability Tester
Media Dispensing System
Laser Theodolite
Scintillation Counter
Dispersion Machine
UV Air Sterilizer
Environmental Monitoring Equipments
Gas Detectors
Digital Differential Pressure Meter
Handheld Ozone Tester
Online Ozone Meter
UV-Absorption Ozone Meter
Multifunctional Environmental Meter
Handheld C2H4 Ethylene Gas Detector LEGD-A10
Sampling:
With internal sampling pump, flow rate is up to 1 L/min, ten grades of pumping suction for selection
Gas:
Ethylene C2H4
Measure Range:
0 to 1000 ppm
Resolution:
1ppm
Add to compare
Catalog
Portable 10 in 1 Multi Gas Detector LMGD-A10
Gas Detected:
O2 CH4 CO2 VOC CO H2S SO2 CL2 NO2 NH3
Detection principle:
Electrochemical principle (O2 CO H2S SO2 CL2 NO2 NH3) Infrared principle (CH4 CO) Photoionization principles (VOC)
Measurement Range:
O2: 0-30% VOL, CH4: 0-50000 PPM, CO2:0-50000 PPM VOC:0-2000 PPM, CO:0-999 PPM, H2S: 0-200 PPM SO2: 0-25 PPM, CL2: 0-50 PPM, NO2: 0-100 PPM, NH3:0-100 PPM
Resolution:
O2: 0.01% VOL, CH4: 1 PPM, CO2:1 PPM VOC:1 PPM, CO:0.1 PPM, H2S: 0.1 PPM SO2: 0.01 PPM, CL2: 0.01 PPM, NO2: 0.01 PPM, NH3:0.01 PPM
Add to compare
Catalog
Portable 2 in 1 gas detector LPTG-A10
Sampling method:
Diffusion
Sensor type:
CO2: solid electrolyte sensor, O2:electrochemical sensor
Detection range:
CO2:0.04 to 5.00 % and O2:0.0 to 30.0 %
Detection accuracy:
CO2:± 30 % rdg (rdg = reading) and O2:± 3 % F.S. (F.S. = full scale)
Add to compare
Catalog
Portable infrared gas detector LIGD-A10
Measurement principle:
Non-dispersive infrared (NDIR)
Gas Detected:
SF6: 0 to 50 ppm range/ 0 to 1000 ppm range (as per req.)
Detection Uncertainty:
<1.5 % F.S
Detection Resolution:
0.1ppm
Add to compare
Catalog
Portable Multiple Gas Detector LPMG-A10
Sampling Method:
Diffusion
Working conditions:
<table cellspacing=0 border=1> <tr> <td style=min-width:50px>Temperature </td> <td style=min-width:50px>-20 to 50°C</td> </tr> <tr> <td style=min-width:50px>Pressure </td> <td style=min-width:50px>0.9 to 1.1 (standard atmospheric pressure) </td> </tr> <tr> <td style=min-width:50px>Humidity </td> <td style=min-width:50px>10 to 95 % RH (no dew condensation)</td> </tr> </table>
Explosion proof grade:
Exia II CT3
Protection grade:
IP65
Add to compare
Catalog
Portable Nitrogen N2 Gas Detector LNGD-A10
Gas Detected:
Nitrogen N2
Detection principle:
Electrochemical principles
Measurement Range:
0 to 100 %.Vol
Resolution:
0.01 %VOL
Add to compare
Catalog
Portable NO<sub>2</sub> Gas Detector LPSG-A21
Gas detected:
NO<sub>2</sub>
Detection principle:
Electrochemistry
Sampling method:
Pumping suction, flow rate can up to 1L/min, ten grades of pumping suction for selection.
Measure range:
0 to1000 ppm
Add to compare
Catalog
Portable Single Gas Detector LPSG-A10
Sampling method:
Diffusion
Measurement principle:
Electrochemical (oxygen, toxic gases), Catalytic combustion (flammable gases), Infrared principle (carbon dioxide gas)
Detector gas:
Flammable gases, oxygen gas, toxic and harmful gases
Response time:
<table cellspacing=0 border=1> <tr> <td style=min-width:50px>CO2 < 10 s </td> </tr> <tr> <td style=min-width:50px>O2, flammable gases < 20 s </td> </tr> <tr> <td style=min-width:50px>CO, H2S, SO2, NO, ClO2, NO2, H2 < 30 s </td> </tr> <tr> <td style=min-width:50px>HCN, NH3, PH3 < 100 s </td> </tr> </table>
Add to compare
Catalog
Portable SO<sub>2</sub>Gas Detector LPSG-A20
Gas detected:
Sulfur dioxide SO<sub>2</sub>
Detection principle:
Electrochemistry
Sampling method:
Pumping suction, flow rate can up to 1L/min, ten grades of pumping suction for selection.
Measure range:
0 to1000 ppm
Add to compare
Catalog
Digital Differential Pressure Meter LDPM-A10
Measuring range:
0 ∼ 125 Pa
Accuracy:
0 ± 0.2 Pa (liner error)<hr> ± 1 %
Operating temperature range:
0 °C ∼ 50 °C
Operational humidity:
˂ 85 RH
Add to compare
Catalog
Digital Differential Pressure Meter LDPM-A20
Measuring range:
± 500 Pa
Repeatability:
± 0.2 % FS
Resolution:
0.1 Pa
Sampling rate:
0.5 s
Add to compare
Catalog
Handheld Ozone Tester LHOT-A10
Measurement range:
0 ppm ∼ 5 ppm
Resolution:
0.001 ppm ( 0 ppm ∼ 5 ppm )
Temperature range:
˗ 40 °C ∼ 120 °C
Humidity range:
0 % ∼ 100 % RH
Add to compare
Catalog
Online Ozone Meter LOOM-A10
Ozone measurement range:
0 ppm ∼ 5 ppm, 0 ppm ∼ 100 ppm, 0 ppm ∼ 300 ppm, 0 ppm ∼ 600 ppm ( Optional )
Flow rate:
1.5 L/min
Accuracy:
0.01 ppm or 3 % of reading
Resolution:
0.001 ppm
Add to compare
Catalog
UV Absorption Ozone Meter LUOM-A10
Ozone measurement range:
0 ppm ∼ 100 ppm/ 0 ppm ∼ 1000 ppm
Flow rate:
1 L/min
Accuracy:
0.01 ppm
Measuring time:
10 seconds
Add to compare
Catalog
6 in 1 Multifunctional Environmental Meter LMEM-A10
Temperature Measurement Range:
-10℃ to 60℃
Temperature Resolution:
0.1°C
Temperature Accuracy:
± 1.5℃
Relative Humidity Range:
20% to 80% RH
Add to compare
Catalog
Floor Balance LFRB-A20
Capacity:
50 kg
Accuracy:
1 g
Speed:
1 s
Value stable time:
2 s
Add to compare