Portable 2 in 1 gas detector LPTG-A10 is a lightweight, hand held design gas detector. It synchronously detects concentration of CO2 gas and that of another gas like O2, CO, NH3, and H2S. LCD display shows real time measurement values. Used in field detection of multiple gases for quality testing and research purpose.

Sampling method Diffusion
Sensor type CO2: solid electrolyte sensor, O2:electrochemical sensor
Detection range CO2:0.04 to 5.00 % and O2:0.0 to 30.0 %
Detection accuracy CO2:± 30 % rdg (rdg = reading) and O2:± 3 % F.S. (F.S. = full scale)
Display resolution CO2:0.01 % and O2:0.1 %
Calibration CO2:0.04 % revise the zero point outdoors, O2:20.9 % revise the zero point outdoors
Display LCD display
Battery shelf life About 20 hours (when using alkaline dry batteries)
Operation temperature -10 to 50 °C
Operation humidity < 90 % RH (non-condensation)
Power supply #5 dry cell, 4/AC 100 to 250 V
Dimension Host Machine (W*D*H) 76 × 27 × 145 mm
Dimension Detector (W*D*H) 28 × 27 × 170 mm
Weight About 250 g (includes detector, batteries)
HS Code 9027100090
  • Equipped with two different types of sensors
  • Synchronous detection of two gases at a time
  • Long probe for narrow room
  • Small volume, Easy to carry
  • Automatic self calibration
Used in bio fuel plants, greenhouse, agriculture, construction, for on field testing of chemical gases and others.

Gas Detectors

Portable SO2Gas Detector LPSG-A20

Portable SO2Gas Detector LPSG-A20

  • Gas detected
  • Sulfur dioxide SO2
  • Detection principle
  • Electrochemistry
  • Sampling method
  • Pumping suction, flow rate can up to 1L/min, ten grades of pumping suction for selection.
Handheld C2H4 Ethylene Gas Detector LEGD-A10

Handheld C2H4 Ethylene Gas Detector LEGD-A10

  • Sampling
  • With internal sampling pump, flow rate is up to 1 L/min, ten grades of pumping suction for selection
  • Gas
  • Ethylene C2H4
  • Measure Range
  • 0 to 1000 ppm
Portable Nitrogen N2 Gas Detector LNGD-A10

Portable Nitrogen N2 Gas Detector LNGD-A10

  • Gas Detected
  • Nitrogen N2
  • Detection principle
  • Electrochemical principles
  • Measurement Range
  • 0 to 100 %.Vol
Portable Multiple Gas Detector LPMG-A10

Portable Multiple Gas Detector LPMG-A10

  • Sampling Method
  • Diffusion
  • Working conditions
  • Temperature -20 to 50°C Pressure 0.9 to 1.1 (standard atmospheric pressure) Humidity 10 to 95 % RH (no dew condensation)
  • Explosion proof grade
  • Exia II CT3

Digital Differential Pressure Meter

Digital Differential Pressure Meter LDPM-A20

Digital Differential Pressure Meter LDPM-A20

  • Measuring range
  • ± 500 Pa
  • Repeatability
  • ± 0.2 % FS
  • Resolution
  • 0.1 Pa
Digital Differential Pressure Meter LDPM-A10

Digital Differential Pressure Meter LDPM-A10

  • Measuring range
  • 0 ∼ 125 Pa
  • Accuracy
  • 0 ± 0.2 Pa (liner error) ± 1 %
  • Operating temperature range
  • 0 °C ∼ 50 °C

Handheld Ozone Tester

Handheld Ozone Tester LHOT-A10

Handheld Ozone Tester LHOT-A10

  • Measurement range
  • 0 ppm ∼ 5 ppm
  • Resolution
  • 0.001 ppm ( 0 ppm ∼ 5 ppm )
  • Temperature range
  • ˗ 40 °C ∼ 120 °C

Online Ozone Meter

Online Ozone Meter LOOM-A10

Online Ozone Meter LOOM-A10

  • Ozone measurement range
  • 0 ppm ∼ 5 ppm, 0 ppm ∼ 100 ppm, 0 ppm ∼ 300 ppm, 0 ppm ∼ 600 ppm ( Optional )
  • Flow rate
  • 1.5 L/min
  • Accuracy
  • 0.01 ppm or 3 % of reading

UV-Absorption Ozone Meter

UV Absorption Ozone Meter LUOM-A10

UV Absorption Ozone Meter LUOM-A10

  • Ozone measurement range
  • 0 ppm ∼ 100 ppm/ 0 ppm ∼ 1000 ppm
  • Flow rate
  • 1 L/min
  • Accuracy
  • 0.01 ppm